High Strength Concrete
This proceedings, High Strength Concrete, consists of papers presented at the first Engineering Foundation Conference on High Strength Concrete,...

Towering Over Xiamen (Available in Structural Engineering Special Issue only)
Composite structural systems are rapidly becoming the preferred choice for high-rise buildings, due to their high strength and stiffness, large ductility, and convenient, economical construction....

Back from the Brink
The Cape Hatteras Lighthouse, the tallest brick lighthouse in the United States, has been moved to prevent it from toppling into the sea as a result of coastal erosion. Engineers from...

Santa Fe Sensation
The new renovation of the Sante Fe Opera Theater is a striking combination of architecture and engineering. The owners wanted to upgrade amenities, especially ADA compliance, and to protect...

State of the Arts
The complicated structural engineering that went into the Nancy Lee and Perry R. Bass Performance Hall in Fort Worth, Texas, allows patrons and performers to focus fully on the arts, and...

Shake, Rattle and Hold (Available in Structural Engineering Special Issue Only)
In-situ lateral load tests of two bridge bents were conducted on Interstate 15 in Salt Lake City, Utah, to determine the strength and ductility of an existing concrete bridge and the improvements...

Bulb-Tees Make More Efficient Long-Span Bridges
The bulb-tee girder has helped erect new bridges with fewer I-beams, and is also shown in studies to be a structurally efficient, cost-effective alternative for long-span bridges....

Timber!
For engineers accustomed to working with steel, using large wood beams in structural applications can be an unusual experience. Three Midwestern construction projects�a nature center,...

Putting the Wraps on Quakes
With bridges deteriorating all over the country at an alarming rate, state DOTs are searching for cost-effective retrofit solutions that will protect our aging bridge inventory from seismic...

Parking Lot Corrosion Cure
The $3 million structural repair and restoration of a large post-tensioned parking structure required engineers to replace 2,400 tendons while keeping the parking garage in service. After...

Northridge Postscript: Lesson on Steel Connections
Immediately after the Northridge earthquake in January 1994, the general concensus was that steel-framed buildings performed extremely well. Later, inspectors were surprised to find weld...

Wood Working
Engineers may be more accustomed to working with concrete and steel, but for certain projects aesthetics, cost or other considerations may make wood the preferred choice. According to...

More Parking Above
Vertical expansion of six (6) new floors of parking garage on top of four (4) floors of existing structure that was built over three decades ago, adding 155,000 square foot of new structure....

Sounding Out Scour
As engineers are aware, detection of bridge scour is the best protection. A method for monitoring scour during low, normal or high water flows would also help alleviate some of the ambiguity...

Dynamic Analysis of a High Speed Transport Model by Using a Piecewise Continuous Timoshenko Beam Model
Conventional treatment of structural dynamic analysis and control is based on the finite element structural model. But such a treatment uses a very large number of elements which is usually...

An Inflatable Antenna for Space-Based Low-Frequency Radio Astronomy
Antennas for a low-frequency orbiting radio telescope must have minimal problems in deployment, a directional beam, and a wide-angle scanning capability. Inflatable antennas with deposited...

High-Strength Concrete Columns in High-Rise Buildings
Strength and ductility of high-strength concrete columns were investigated by examining available test data. The results are summarized in terms of load and ductility capacities of columns....

Application of Concrete-Filled Steel Tubular Columns in Tall Buildings in Earthquake Area
In this paper an outline is given of the background, the design concept, structural features, construction and economy of the concrete-filled steel tubular coumns of tall buildings in...

Recent Developments in Seismic Response of Composite Structures
Lack of sufficient data has limited a wider application of structures using mixed steel-concrete construction in seismically active regions. This paper summarizes some recent studies at...

One Peachtree Center: Atlanta Georgia
Presented in this paper are the architectural and structural concepts of One Peachtree Center built in the city of Atlanta. This 62-story tall building has changed the downtown skyline...

 

 

 

 

Return to search